What are the advantages of differential protection for transformers?

What are the advantages of differential protection for transformers?

A transformer's differential protection offers several benefits over other types of protection. The Buchholz relay can detect flaws in the transformer that occur within the insulating oil. Normally, differential relays respond to faults that occur inside the transformer's differential protection zone. However, if a fault occurs outside this zone, the relay will not activate to indicate the problem.

This advantage means that a faulty conductor within the outer shell of the transformer can be detected by the Buchholz relay before any damage occurs to the insulation on the inside of the transformer. In addition, the differential protection prevents false activations due to ground currents or noise. This feature is particularly important when used with power supplies that use magnetic coupling through the primary winding to provide energy from an external source into a secondary circuit.

Differential protection also allows two separate circuits to be protected with one relay. For example, two separate power supplies could be connected to a single transformer and each supply would have its own set of contacts to indicate a failure. Or, one circuit could be completely removed from the transformer without activating the relay itself. This would allow the equipment attached to this circuit to continue to function even if some parts of the transformer were damaged.

Differential protection is useful because it allows more than one circuit to be protected with less number of components required.

Why is transformer testing required?

This oil is subjected to mechanical and electrical stress, as well as chemical pollution, over time. When functionality is diminished, power outages might occur. Regular transformer oil testing is critical for maintaining and extending the life of the power transformer and avoiding major malfunctions. Testing also ensures that you are not being charged more for obsolete oil.

Transformer oil testing is needed to determine if the oil is still effective at keeping the transformer cool during a overload. If the temperature starts to rise, the oil may need to be changed. Transformer oil that is too hot can cause burning or smoking. This could indicate that one or more of the oil seals has been damaged, allowing hot oil into the core area where it can heat up and cause damage.

Oil that is no longer effective at cooling the transformer will result in higher than normal temperatures during an overload. This can lead to premature failure of other parts of the system, such as circuit breakers, wiring, and terminals. The transformer itself could be destroyed before anyone realizes that it needs to be replaced.

To prevent overheating and malfunctioning of your transformer, it is necessary to test the oil regularly. The frequency of testing depends on how often you change the oil, but it's recommended that you test your oil every month or two during the first year and then once a year after that.

How is the current transformer used in protection?

The protection current transformer is used to lower currents in power systems by creating proportionate currents in the secondary windings of the unit while remaining isolated from the main circuit. As a result, the protective current transformer permits the circuit's unaffected sections to continue to operate. When an overload or short circuit occurs, the increased current through the primary of the transformer will cause a proportional increase in the secondary current.

There are two types of protection current transformers: single-phase and three-phase. The single-phase current transformer has one secondary winding connected to a single primary winding located on the core of the transformer. This type of current transformer is used for protecting single circuits from overloaded motors, heaters, and other equipment. The three-phase current transformer has three separate secondary windings connected to three separate primary windings located on the core of the transformer. This type of current transformer is used for tripping overcurrent conditions on multiple circuits simultaneously. The three-phase current transformer provides improved performance over the single-phase version because it allows more time for each circuit to be separated from the others if they should fail at the same time.

The amount of current drawn by an electrical appliance such as a motor, heater, or air conditioner is called its "load". The voltage applied to the load determines how much current will flow through it.